<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>7022</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: Carriage control board error: over temperature
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The carriage driver has reported a fault.  Control signals: status0 is low
(active) and status1 is high (inactive).  Check the cables running to and
from the carriage driver board.  Also check the voltage levels on the board.
</text></DescriptionText>
<DescriptionText><text>
If an over temperature fault has occured, the OT and FAULT LED will be asserted
on the carriage drive board. This error may cause a momentary fault to be
displayed at the diagnostic terminal. To verify if this has occured, check
that the OT LED is asserted before reseting or intializing the carriage.
</text></DescriptionText>
<DescriptionText><text>
This error is only applicable if the new carriage driver is installed.  In that
case, the "sys hpd (high_pwr_drives)" will be set to 1.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on CANCEL IMAGE. If the machine does not recover, turn the power
to the output machine off and on again.  Please contact Creo Service to report
this error.
</text></DescriptionText>
</OperatorAction>
<Cause>
Carriage amp failure
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/sys_cfg_hpd.xml</LinkAddress><LinkTitle>NVS: sys hpd</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:29 2008 PST
</Updated>
<Links>
</Links>
</Error>